DTP32TR AutoScan Farbdensitometer
Article number: 31597
Listed in category: Measurement / Remission-Densitometer > DTP32TR AutoScan Farbdensitometer from brakensiek.de
DTP32TR AutoScan color densitometer
- Measure T status, visual density according to ISO and the tone of films, polyester plates and proofing materials.
- Compatible with many third-party calibration programs
Automatic Strip Reading Densitometer for Calibration of Color Output Devices
The DTP32 provides calibration and quality control for PostScript ® color copiers, color printers, color proofing and systems.
The calibration of any color output device will drift over time, causing color and fluctuations in screen values. Colors may vary due to changes in room temperature, humidity, or changes in paper, toner, or other automatic scanning densitometer materials.The DTP32 Ensures consistent, accurate color on every job.
Calibration Software Interface
The DTP32 interfaces directly with most calibration software through a direct cable link to a computer.
Simple, Step-By-Step Operation
• Output a calibration test print from a color printer or copier.
• Feed it through the car's DTP32 scanning mechanism.
• The DTP32 sends readings to the color density control software via serial interface.
• Within minutes, the printer is calibrated and ready to deliver accurate, consistent prints.
Features
• Is supported by a Majority of 3rd party software, RIP and printer manufacturers. Visit X-Rite's web site "Color Enabled" for information: www.x-rite.com/support/partners.asp
• Status T color response (the industry standard for wideband reflection densitometer).
• Interfaces with IBM-compatible Macintosh ® Sun, and SGI platforms.
• Fast, time-saving process - five calibration completes in under minutes.
• Optional DTP32TR offers transmission and reflection combination technology.
• Measures paper and film output.
• Small desktop footprint.
• Accessories included:
- Calibration reference
- Operation manual
- PC / Mac interface cables
- Power supply
Benefits
• Color consistency throughout a job and over time.
• Sharp, accurate, color.
• Predictable, repeatable results.
• Quality control of on-demand, including color proofing, large format and color prints.
• Fast, easy-to-use system
• No trial and error.
• Fewer service calls, lower overall costs.
Specification
Measuring Geometry
Reflection: by ANSI PH2.17/ISO 5/4
multi-sensor array
Optional Transmission: 2 per ANSI PH
19/ISO 5/2
Light Source
Gas pressure filament lamp with
approx. 2850 ° K color temp
Lamp life, approx. 1,000,000 scans @ 11 "
Receiver
Blue enhanced silicon photodiodes
System Response
ANSI / ISO Status T
Measurement Range
Reflection: 0.00d to 2.50D absolute
Transmission: 0.00 to 4.00d absolute
Repeatability
± 0.01D, 0 to 3.0D
± 1%, 3.0 to 4.0D
Linearity
± 0.01D or ± 1%, 0 to 3.5D
± 3%, 3.5 to 4.0D
Zero Stability
± 0.01D max
Calibration
Automatic w / QuickCal ™
Measuring Area
2mm x 4mm, 2mm in the
direction of travel
Measuring Location
3.0 "from rightmost stop
Adjustable stops in .5 "increments
from .5 to 3.0 "
Fixed slot for up to 38mm film
Sample Characteristics
Thickness: 0.003 to .015 "
Size: Unit is open at one end and
can accept any size sheet Sun
long as it can be pulled evenly
through the unit.
Patch size: .400 "(10.16mm) in minutes.
direction of travel by .350 "min. wide
1mm wide 1.0D contrast space
between patches or .5 D min
difference between patches
Transport Speed
~ 1.2 "/ sec
Measurement rate
Adequate to measure patches.
4 "minimum in the direction of travel
Communication Interface / Protocol
(As described in the X-Rite DTP
RCI manual)
I / O port: (10 circuit modular jack)
Patented bi-directional RS-232 at
<_ 19.2k baud
Remote control: via standard X-Rite
DTP series RCI commands
This protocol Allows for RCI
downloading of custom measurement
strips and display data remotely,
calibration, and remote parameters
configuration.
Data format: Transmitted in Density,
+ Dot-Dot, or Reflectance. Output
has x10 capability.
Power Requirements
& Connection
+12 V @ 700ma
2 circuit jack with 03.05 plus tip using @
either SE30-61 (115V) or SE30-62
(230VAC) adapter
Physical
Dimensions
2.75 "H
7.2 "W
6.0 "D
Weight
large 5.0 lbs.
net lbs 2.5.
Environmental
Operating temp. range +10 ° to +35 ° C;
30% to 60% RH.
Storage temp. range
-40 ° to +60 ° C, 5% to 95% RH.
Accessories Provided
Calibration Reference
Operation Manual
PC & Mac interface cables
AC adapter
Either 115VAC (P / N SE30-61) or
230VAC (P / N SE30-62)
Optional Accessories
RCI Interface Manual
(P / N DTP32-506)
Models
DTP32R
Reflection only 115VAC
DTP32TR
Reflection / transmission 115VAC
DTP32RX
Reflection only 230VAC
DTP32TRX
Reflection / transmission 230VAC
- Measure T status, visual density according to ISO and the tone of films, polyester plates and proofing materials.
- Compatible with many third-party calibration programs
Automatic Strip Reading Densitometer for Calibration of Color Output Devices
The DTP32 provides calibration and quality control for PostScript ® color copiers, color printers, color proofing and systems.
The calibration of any color output device will drift over time, causing color and fluctuations in screen values. Colors may vary due to changes in room temperature, humidity, or changes in paper, toner, or other automatic scanning densitometer materials.The DTP32 Ensures consistent, accurate color on every job.
Calibration Software Interface
The DTP32 interfaces directly with most calibration software through a direct cable link to a computer.
Simple, Step-By-Step Operation
• Output a calibration test print from a color printer or copier.
• Feed it through the car's DTP32 scanning mechanism.
• The DTP32 sends readings to the color density control software via serial interface.
• Within minutes, the printer is calibrated and ready to deliver accurate, consistent prints.
Features
• Is supported by a Majority of 3rd party software, RIP and printer manufacturers. Visit X-Rite's web site "Color Enabled" for information: www.x-rite.com/support/partners.asp
• Status T color response (the industry standard for wideband reflection densitometer).
• Interfaces with IBM-compatible Macintosh ® Sun, and SGI platforms.
• Fast, time-saving process - five calibration completes in under minutes.
• Optional DTP32TR offers transmission and reflection combination technology.
• Measures paper and film output.
• Small desktop footprint.
• Accessories included:
- Calibration reference
- Operation manual
- PC / Mac interface cables
- Power supply
Benefits
• Color consistency throughout a job and over time.
• Sharp, accurate, color.
• Predictable, repeatable results.
• Quality control of on-demand, including color proofing, large format and color prints.
• Fast, easy-to-use system
• No trial and error.
• Fewer service calls, lower overall costs.
Specification
Measuring Geometry
Reflection: by ANSI PH2.17/ISO 5/4
multi-sensor array
Optional Transmission: 2 per ANSI PH
19/ISO 5/2
Light Source
Gas pressure filament lamp with
approx. 2850 ° K color temp
Lamp life, approx. 1,000,000 scans @ 11 "
Receiver
Blue enhanced silicon photodiodes
System Response
ANSI / ISO Status T
Measurement Range
Reflection: 0.00d to 2.50D absolute
Transmission: 0.00 to 4.00d absolute
Repeatability
± 0.01D, 0 to 3.0D
± 1%, 3.0 to 4.0D
Linearity
± 0.01D or ± 1%, 0 to 3.5D
± 3%, 3.5 to 4.0D
Zero Stability
± 0.01D max
Calibration
Automatic w / QuickCal ™
Measuring Area
2mm x 4mm, 2mm in the
direction of travel
Measuring Location
3.0 "from rightmost stop
Adjustable stops in .5 "increments
from .5 to 3.0 "
Fixed slot for up to 38mm film
Sample Characteristics
Thickness: 0.003 to .015 "
Size: Unit is open at one end and
can accept any size sheet Sun
long as it can be pulled evenly
through the unit.
Patch size: .400 "(10.16mm) in minutes.
direction of travel by .350 "min. wide
1mm wide 1.0D contrast space
between patches or .5 D min
difference between patches
Transport Speed
~ 1.2 "/ sec
Measurement rate
Adequate to measure patches.
4 "minimum in the direction of travel
Communication Interface / Protocol
(As described in the X-Rite DTP
RCI manual)
I / O port: (10 circuit modular jack)
Patented bi-directional RS-232 at
<_ 19.2k baud
Remote control: via standard X-Rite
DTP series RCI commands
This protocol Allows for RCI
downloading of custom measurement
strips and display data remotely,
calibration, and remote parameters
configuration.
Data format: Transmitted in Density,
+ Dot-Dot, or Reflectance. Output
has x10 capability.
Power Requirements
& Connection
+12 V @ 700ma
2 circuit jack with 03.05 plus tip using @
either SE30-61 (115V) or SE30-62
(230VAC) adapter
Physical
Dimensions
2.75 "H
7.2 "W
6.0 "D
Weight
large 5.0 lbs.
net lbs 2.5.
Environmental
Operating temp. range +10 ° to +35 ° C;
30% to 60% RH.
Storage temp. range
-40 ° to +60 ° C, 5% to 95% RH.
Accessories Provided
Calibration Reference
Operation Manual
PC & Mac interface cables
AC adapter
Either 115VAC (P / N SE30-61) or
230VAC (P / N SE30-62)
Optional Accessories
RCI Interface Manual
(P / N DTP32-506)
Models
DTP32R
Reflection only 115VAC
DTP32TR
Reflection / transmission 115VAC
DTP32RX
Reflection only 230VAC
DTP32TRX
Reflection / transmission 230VAC
purchase list
last update:
20.11.2012